omron — User Parameter Automatic Selection: A2-33

4.5 Application Presets ■ Detailed Description To save specific parameters to A2-01 to A2-32, first set the access level to allow access to all parameters (A1-02 = “2”). After selecting the parameters to be saved to A2-01 through A2- 32, set the access level to allow access only to the selected list of User Parameters. Set A1- 01 to “1” to restrict access so users can only set and reference the specific parameters saved as User Parameters. ◆ User Parameter Automatic Selection: A2-33 A2-33 determines whether parameters that have been edited are saved to the User Parameters (A2-17 to A2-32) for quick, easy access. Start-Up Programming & Operation 4 ■ Detailed Description 0:

Do not save history of recently viewed parameters. To manually select the parameters listed in the Preferred Parameter group, set A2-33 to “0”. 1: Save history of recently viewed parameters. By setting A2-33 to 1, all parameters that were recently edited will be saved to A2-17 through A2-32. A total of 16 parameters are saved in order, with the most recently edited parameter set to A2-17. OYMC TOEP C71060622-01-OY V1000 User Manual 117 No. Parameter Name Setting range Default A2-33 User Parameter Automatic Selection 0: Do not save history of recently viewed parameters. 1: Save history of recently viewed parameters. 0, 1