omron — Initialize Parameter Values: A1-03

4.6 Basic Drive Setup Adjustments 4.6 Basic Drive Setup Adjustments This section explains the basic settings required for initial drive operation. Checking these basic parameter settings during start-up will help to ensure a successful drive start-up. If more information is required for parameters not listed in this section, Refer to Parameter List on page 293 as required for a complete listing of drive parameters. ◆ Control Mode Selection: A1-02 ■ Available Control Modes Three motor control modes are available. Select the control mode that best suits the application in which the drive will be used. ◆ Initialize Parameter Values:

A1-03 Parameter A1-03 (Initialize Parameters) resets all parameters to the original default values. Note: Save all changed parameter settings by setting o2-03=”1” before initializing the drive. Your settings will be lost if a 2-wire or 3-wire initialization using 2220, or 3330 if performed without first saving user parameters. Refer to Backing Up Parameter Values: o2-03 on page 160 . ■ Different Methods of Drive initialization 1110: Resets all parameters to user-defined default values A user-initialization resets all parameters to a user-defined set of default values previously saved to the drive. Set parameter o2-03 to “2” to clear those values. Note:

Set o2-03 to “1” to save the current parameter settings and changes for a “user-initialization.” After saving all parameter setting changes, parameter o2-03 automatically returns to 0. Refer to Verifying Parameter Settings and Backing Up Changes on page 159 . 2220: 2-Wire Initialization Returns all parameters to factory default values for 2-wire control. 118 OYMC TOEP C71060622-01-OY V1000 User Manual Control Mode Parameter Main Applications V/f Control A1-02 = 0 (default) • General variable speed applications • For running multiple motors from a single drive • When replacing a drive in which motor data settings are unknown.

Open Loop Vector Control A1-02 = 2 • General variable speed applications • Applications requiring high precision, high speed control. PM Open Loop Vector Control A1-02 = 5 Variable torque applications employing permanent magnet motors and energy savings.