4.6 Basic Drive Setup Adjustments ■ Using S-Curve Characteristics during Acceleration/Deceleration Using S-curve characteristics to smooth acceleration and deceleration minimizes abrupt shock to the load. Set S-curve characteristic time during acceleration/deceleration at start and acceleration/deceleration at stop. Note: 1. Setting S-curve characteristics will lengthen accel/decel times as follows: Accel Time = Selected Accel Time + (C2-01 + C2-02)/2 Decel Time = Selected Decel Time + (C2-03 + C2-04)/2 2. Set longer S-curve times using PM Open Loop Vector Control. Setting Example Figure 4.22 illustrates S-curve characteristics switching between forward and reverse.
Figure 4.22 Figure 4.22 S-Curve Characteristics ◆ Drive Duty Mode and Carrier Frequency Selection: C6-01 and C6-02 The drive has two different duty modes from which to select based on the load characteristics. The drive rated current, overload capacity, carrier frequency, and maximum output frequency will change depending upon the duty mode selection. Use parameter C6-01 (Duty Cycle) to select Heavy Duty (HD) or Normal Duty (ND) for the application. The factory setting is HD. Refer to Specifications on page 279 for details about the rated current. ■ Drive Duty Mode Selection:
C6-01 HD and ND Mode Selections 130 OYMC TOEP C71060622-01-OY V1000 User Manual Forward Run Command Reverse Run Command C2-02 C2-03 C2-04 Output Frequency C2-01 C2-01 C2-04 C2-02 C2-03 C2-02 C2-03 C2- 04 - 04 Mode Heavy Duty Rating Normal Duty Rating C6-01 0 1