omron — Auto-Tuning

4.7 Test Run Enter Data from the Motor Nameplate After selecting the type of Auto-Tuning, enter the required data from the motor nameplate. Note: These instructions continue from Step 7 in Selecting the Type of Auto-Tuning. 154 OYMC TOEP C71060622-01-OY V1000 User Manual Step Display/Result 4. Press to display the value for T1-01. ⇒ 5. Press to select the digit to edit. ⇒ 6. Press and set the drive to perform Rotational Auto-Tuning (00). ⇒ 7. Save the setting by pressing . ⇒ 8. The display automatically returns to the screen shown in Step 3. ⇒ 9. Press the key until back at the Top Screen. ⇒ Step Display/Result 1. Press to access the motor output power parameter T1-02. ⇒ 2.

Press to view the default setting. ⇒ 3. Press to select the digit to edit. ⇒ Press and enter “0.2.” Enter value based on motor 4. nameplate data. ⇒ 5. Press to save the setting. ⇒ 6. The display automatically returns to the screen shown in Step 1. ⇒