omron — No-Load Operation

4.7 Test Run Normally not displayed. Voltage and frequency settings for vector motors and drive motors are often lower than for standard motors. Be sure to enter Auto-Tuning data according to the motor nameplate and motor data sheets. If the no-load voltage and frequency values are shown, enter those values into T1-03 and T1-05. Start-Up Programming & Operation Basic motor nameplate data can be used to auto-tune a motor. However, improved performance can be achieved by using precise data for base voltage and base frequency.

If the no-load base voltage and no-load base frequency (voltage and frequency that are required to operate the motor at rated speed without load) are known, enter this data when executing auto-tuning to improve performance. ■ Precision Settings for Auto-Tuning 4 ◆ No-Load Operation This section explains how to operate the drive with the motor uncoupled from the load during a test run. ■ Before Starting the Motor Check the following items before operation: • Ensure the area around the motor is safe. • Set the proper motor rated current to T1-04 to prevent overheating or other damage from motor overload.

• Ensure external emergency stop circuitry is working properly and other safety precautions have been taken. ■ During Operation Check the following items during operation: • The motor should rotate smoothly (i.e., no abnormal noise or oscillation). OYMC TOEP C71060622-01-OY V1000 User Manual 157 No. Name Description Range Def. Control Mode V/f OLV T1-11 Motor Iron Loss Provides iron loss for determining Energy Saving coefficient. When power is cycled, the value set to E2-10 will appear (the motor iron loss). If T1-02 is changed, an initial value for the motor capacity will appear that is close to the capacity that was changed.

0 to 65535 14W A − Parameter Normal Settings Precision Tuning T1-03 Enter the motor rated voltage Enter the no-load base voltage when the motor is operating at its rated revolutions per minute T1-05 Enter the motor base frequency Enter the no-load base frequency when the motor is operating at its rated revolutions per minute