5.4 Fault Detection 190 OYMC TOEP C71060622-01-OY V1000 User Manual The motor winding is damaged. • Check the resistance between motor lines. • Replace the motor if the winding is damaged. The output terminal is loose. • Apply the tightening torque specified in this manual to fasten the terminals. Refer to Wire Size on page 68. The motor being used is less than 5% of the drive rated current. Check the drive and motor capacities. An output transistor is damaged. Replace the drive. A single phase motor is being used. The drive being used cannot operate a single phase motor. LED Operator Display Fault Name LF2 Output current imbalance One or more of the phases in the output current is lost.
Cause Possible Solution Phase loss has occurred on the output side of the drive. • Check for faulty wiring or poor connections on the output side of the drive. • Correct the wiring. Terminal wires on the output side of the drive are loose. Apply the tightening torque specified in this manual to fasten the terminals. Refer to Wire Size on page 68. No signal displays from the gate driver board. Replace the drive. Contact OYMC or an OYMC representative for assistance. Motor impedance or motor phases are uneven. • Measure the line-to-line resistance for each motor phase. Ensure all values are the same. • Replace the motor. Contact OYMC or an OYMC representative for assistance.
LED Operator Display Fault Name oC Overcurrent Drive sensors have detected an output current greater than the specified overcurrent level. Cause Possible Solution The motor has been damaged due to overheating or the motor insulation is damaged. Check the insulation resistance. Replace the motor. One of the motor cables has shorted out or there is a grounding problem. • Check the motor cables. • Remove the short circuit and power the drive back up. • Check the resistance between the motor cables and the ground terminal . • Replace damaged cables. The load is too heavy. • Measure the current flowing into the motor.
• Replace the drive with a larger capacity unit if the current value exceeds the rated current of the drive. • Determine if there is sudden fluctuation in the current level. • Reduce the load to avoid sudden changes in the current level or switch to a larger drive.