5.4 Fault Detection OYMC TOEP C71060622-01-OY V1000 User Manual 195 Cycle times are too short during acceleration and deceleration. Increase the settings for the acceleration and deceleration times (C1-01 through C1-08). Voltage is too high for the V/f characteristics. • Adjust the preset V/f pattern (E1-04 through E1-10). This will mainly involve reducing E1-08 and E1-10. • Be careful not to lower E1-08 and E1-10 excessively because this reduces load tolerance at low speeds. Drive capacity is too small. Replace the drive with a larger model. Overload occurred when operating at low speeds. • Reduce the load when operating at low speeds.
• Replace the drive with a model that is one frame size larger. • Lower the carrier frequency (C6-02). Excessive torque compensation. Reduce the torque compensation gain (C4-01) until there is no speed loss but less current. Speed Search related parameters are not set correctly. • Check the settings for all Speed Search related parameters. • Adjust the current used during Speed Search and the Speed Search deceleration time (b3-03 and b3-02 respectively). • After Auto-Tuning the drive, enable the Speed Search Estimation Type (b3-24 = “1”). Output current fluctuation due to input phase loss. Check the power supply for phase loss.
LED Operator Display Fault Name oL3 Overtorque Detection 1 5 The current has exceeded the value set for torque detection (L6-02) for longer than the allowable time (L6-03). Cause Possible Solution Parameter settings are not appropriate for the type of load. Check the settings of parameters L6-02 and L6-03. There is a fault on the machine side (e.g., the machine is locked up). Check the status of the load. Remove the cause of the fault. LED Operator Display Fault Name oL4 Overtorque Detection 2 The current has exceeded the value set for Overtorque Detection 2 (L6-05) for longer than the allowable time (L6-06).
Cause Possible Solution Parameter settings are not appropriate for the type of load. Check the settings of parameters L6-05 and L6-06. There is a fault on the machine side (e.g., the machine is locked up). Check the status of the load. Remove the cause of the fault. LED Operator Display Fault Name oL7 High-Slip Braking OL The output frequency stayed constant for longer than the time set in n3-04 during High-slip Braking.