5.4 Fault Detection OYMC TOEP C71060622-01-OY V1000 User Manual 199 LED Operator Display Fault Name rr Dynamic Braking Transistor The built-in dynamic braking transistor failed. Cause Possible Solution The braking transistor is damaged. • Cycle power to the drive and check if the fault reoccurs. Refer to Diagnosing and Resetting Faults on page 222. • Replace the drive if the fault continues. The control circuit is damaged. LED Operator Display Fault Name SEr Too Many Speed Search Restarts The number of speed search restarts exceeded the number set to b3-19. Cause Possible Solution Speed Search parameters are set to the wrong values.
• Reduce the detection compensation gain during Speed Search (b3-10). • Increase the current level when attempting Speed Search (b3-17). • Increase the detection time during Speed Search (b3-18). • Repeat Auto-Tuning. The motor is coasting in the opposite direction of the run command. Enable Bi-directional Speed Search (b3-14 = “1”). LED Operator Display Fault Name STO Pull-Out Detection Motor pull-out has occurred. 5 Cause Possible Solution The wrong motor code has been set (Yaskawa motors only). • Enter the correct motor code for the PM being used into E5-01. • For special-purpose motors, enter the correct data to all E5 parameters according to the Test Report provided for the motor.
Load is too heavy. • Increase the value set to n8-55 (Load Inertia for PM). • Increase the value set to n8-51 (Pull-In Current during Accel/Decel for PM). • Reduce the load. • Increase the motor or drive capacity. Load inertia is too heavy. Increase n8-55 (Load Inertia for PM). Acceleration and deceleration times are too short. • Increase the acceleration and deceleration times (C1-01 through C1-08). • Increase the S-curve acceleration and deceleration times (C2-01). LED Operator Display Fault Name UL3 Undertorque Detection 1 The current has fallen below the minimum value set for torque detection (L6-02) for longer than the allowable time (L6-03).
Cause Possible Solution Parameter settings are not appropriate for the type of load. Check the settings of parameters L6-02 and L6-03. There is a fault on the machine side. Check the load for any problems.