omron — Alarm Codes, Causes, and Possible Solutions

5.5 Alarm Detection Troubleshooting 5 OYMC TOEP C71060622-01-OY V1000 User Manual 205 LED Operator Display Minor Fault Name dnE Drive Disabled Cause Possible Solutions Minor Fault Output (H2-†† = 10) “Drive Enable” is set to a multi-function contact input (H1- = 6A) and that signal was switched off. Check the operation sequence. YES LED Operator Display Minor Fault Name EF Forward/Reverse Run Command Input Error Both forward run and reverse run closed simultaneously for over 0.5 s. Cause Possible Solutions Minor Fault Output (H2-†† = 10) Sequence error Check the forward and reverse command sequence and correct the problem. Note: When minor fault EF detected, motor ramps to stop.

YES LED Operator Display Minor Fault Name EF0 Option Card External Fault An external fault condition is present. Cause Possible Solutions Minor Fault Output (H2-†† = 10) An external fault was received from the PLC with F6-03 = 3 (causing the drive to continue running when an external fault occurs). • Remove the cause of the external fault. • Remove the external fault input from the PLC. YES There is a problem with the PLC program. Check the PLC program and correct problems. YES LED Operator Display Minor Fault Name EF1 External fault (input terminal S1) External fault at multi-function input terminal S1.

EF2 External fault (input terminal S2) External fault at multi-function input terminal S2. EF3 External fault (input terminal S3) External fault at multi-function input terminal S3. EF4 External fault (input terminal S4) External fault at multi-function input terminal S4.