omron — Alarm Codes, Causes, and Possible Solutions

5.5 Alarm Detection 208 OYMC TOEP C71060622-01-OY V1000 User Manual A special-purpose motor is being used, or the drive is attempting to run a motor greater than the maximum allowable capacity. • Check the motor capacity. • Use a motor appropriate for the drive. Ensure the motor is within the allowable capacity range. YES The current level increased due to Speed Search after a momentary power loss or while attempting to perform a fault restart. The alarm will appear only briefly. There is no need to take action to prevent the alarm from occurring in such instances. YES LED Operator Display Minor Fault Name oH Heatsink Overheat The temperature exceeded the maximum allowable value.

Cause Possible Solutions Minor Fault (H2- †† = 10) Surrounding temperature is too high • Check the surrounding temperature. • Improve the air circulation within the enclosure panel. • Install a fan or air conditioner to cool surrounding area. • Remove anything near drive that may cause extra heat. YES Internal cooling fan has stopped. • Replace the cooling fan. Refer to Cooling Fan Replacement on page 250. • After replacing the drive, reset the cooling fan maintenance parameter to (o4-03 = “0”). YES Airflow around the drive is restricted. • Provide proper installation space around the drive as indicated in the manual. Refer to Correct Installation Spacing on page 40.

• Allow for the specified space and ensure that there is sufficient circulation around the control panel. YES • Check for dust or foreign materials clogging cooling fan. • Clear debris caught in the fan that restricts air circulation. YES LED Operator Display Minor Fault Name oH2 Drive Overheat Warning “Drive Overheat Warning” was input to a multi-function input terminal, S1 through S6 (H1- = B). Cause Possible Solutions Minor Fault (H2- †† = 10) An external device triggered and overheat warning in the drive. • Search for the device that tripped the overheat warning. • Solving the problem will clear the warning.

YES LED Operator Display Minor Fault Name oH3 Motor Overheat The motor overheat signal entered to a multi-function analog input terminal exceeded the alarm level (H3-02 or H13-10 = E).