5.5 Alarm Detection Troubleshooting 5 OYMC TOEP C71060622-01-OY V1000 User Manual 209 Cause Possible Solutions Minor Fault (H2- = 10) Motor thermostat wiring is fault (PTC input). Repair the PTC input wiring. YES There is a fault on the machine side (e.g., the machine is locked up). • Check the status of the machine. • Remove the cause of the fault. YES Motor has overheated. • Check the load size, accel/decel times, and cycle times. • Decrease the load. • Increase accel and decel times (C1-01 to C1-08). • Adjust the preset V/f pattern (E1-04 through E1-10). This will mainly involve reducing E1-08 and E1-10. Note:
Do not lower E1-08 and E1-10 excessively, because this reduces load tolerance at low speeds. • Check the motor-rated current. • Enter motor-rated current on motor nameplate (E2-01). • Ensure the motor cooling system is operating normally. • Repair or replace the motor cooling system. YES LED Operator Display Minor Fault Name oL3 Overtorque 1 Drive output current (or torque in OLV) was greater than L6-02 for longer than the time set in L6-03. Cause Possible Solutions Minor Fault (H2- = 10) Inappropriate parameter settings. Check parameters L6-02 and L6-03. YES There is a fault on the machine side (e.g., the machine is locked up). • Check the status of the machine.
• Remove the cause of the fault. YES LED Operator Display Minor Fault Name oL4 Overtorque 2 Drive output current (or torque in OLV) was greater than L6-05 for longer than the time set in L6-06. Cause Possible Solutions Minor Fault Output (H2- = 10) Parameter settings are not appropriate. Check parameters L6-05 and L6-06. YES There is a fault on the machine side (e.g., the machine is locked up). • Check the status of the machine being used. • Remove the cause of the fault. YES LED Operator Display Minor Fault Name oS Overspeed (for Simple V/f with PG) Pulse input (RP) indicates that motor speed feedback exceeded F1-08 setting.