omron — Motor Does Not Rotate Properly after Pressing RUN Button or After Entering External Run Command

5.9 Troubleshooting without Fault Display Troubleshooting Note: Check the motor specifications for the forward and reverse directions. The motor specifications will vary depending on the manufacturer of the motor. ■ Motor Rotates in One Direction Only 5 ■ Motor is Too Hot OYMC TOEP C71060622-01-OY V1000 User Manual 227 Cause Possible Solutions The forward direction for the motor is set-up incorrectly. • Typically, forward is designated as being counterclockwise when looking from the motor shaft (refer to the figure below). 1 2 • 1. Forward Rotating Motor (looking down the motor shaft) 2.

Motor Shaft The motor is running at almost 0 Hz and the Speed Search estimated the speed to be in the opposite direction. • Disable bi-directional search (b3-14 = “0”) so that Speed Search is performed only in the specified direction. Cause Possible Solutions The drive prohibits reverse rotation. • Check parameter b1-04. • Set the drive to allow the motor to rotate in reverse (b1-04 = “0”). A Reverse run signal has not been entered, although 3-wire sequence is selected. • Make sure that one of the input terminals S3 to S6 used for the 3-wire sequence has been set for reverse. Cause Possible Solutions The load is too heavy.

• If the load is too heavy for the motor, the motor will overheat as it exceeds its rated torque value for an extended period of time. • Keep in mind that the motor also has a short-term overload rating in addition to the possible solutions provided below: • Reduce the load. • Increase the acceleration and deceleration times. • Check the values set for the motor protection (L1-01, L1-02) as well as the motor rated current (E2-01). • Increase motor capacity. The air around the motor is too hot. • Check the ambient temperature. • Cool the area until it is within the specified temperature range. The drive is operating in a vector control mode but Auto-Tuning has not yet been performed.

• Perform Auto-Tuning. • Calculate the motor value and reset the motor parameters. • Change the motor control method to V/f Control (A1-02 = “0”).