omron — Motor Does Not Rotate Properly after Pressing RUN Button or After Entering External Run Command

5.9 Troubleshooting without Fault Display ■ PID output fault ■ Insufficient Motor Torque ■ Motor Rotates After the Drive Output is Shut Off ■ OV or Speed Loss Occurs When Starting into a Rotating Load 234 OYMC TOEP C71060622-01-OY V1000 User Manual Cause Possible Solutions No PID feedback input. • Check the multi-function analog input terminal settings. • Set multi-function analog input terminal A1 or A2 for PID feedback (H3-02 or H3-10 = “B”). • A signal input to the terminal selection for PID feedback is necessary. • Check the connection of the feedback signal. • Check the various PID-related parameter settings.

• No PID feedback input to the terminal causes the value detected to be 0, causing a PID fault and the drive to operate at max frequency. The level of detection and the target value do not correspond with each other. • PID control keeps the difference between target and detection values at 0. Set the input level for the values relative to one another. • Use analog input gains H3-03/11 to adjust PID target and feedback signal scaling. Reverse drive output frequency and speed detection. When output frequency rises, the sensor detects a speed decrease. Set PID output for reverse characteristics (b5-09 = “1”).

Cause Possible Solutions Auto-Tuning has not yet been performed (required for OLV Control). Perform Auto-Tuning. The control mode was changed after performing Auto-Tuning. Perform Auto-Tuning again. Only Line-to-Line Resistance Auto-Tuning was performed. Perform Rotational Auto-Tuning. Cause Possible Solutions Low DC Injection Braking and the drive cannot decelerate properly. • Adjust the DC Injection braking settings. • Increase the value of b2-02 (DC Injection Braking Current). • Increase the b2-04 (DC Injection Braking Time at Stop). Cause Possible Solutions The load is already rotating when the drive is trying to start it. • Stop the motor using DC Injection braking. Restart the motor.

• Increase the value of b2-03 (DC Injection Braking Time at start). • Enable Speed Search at start (b3-01 = “1”). • Set a multi-function input terminal for external Speed Search command (H1- =“61”or “62” during restart). Figure 4.17 on on page 126.