B.2 Parameter Table Parameter List B OYMC TOEP C71060622-01-OY V1000 User Manual 333 H3 Multi-Function Analog Input Settings H3- Setting Function Maximum Input Level Possible Control Mode Pg. V/f OL V PM 0 Frequency Bias Max output frequency (E1-04).Same value can be set using H3-02 and H3-10. O O O — 1 Frequency Gain Frequency reference (voltage) O O O — 2 Auxiliary Frequency Reference (used as a multi step speed 2) Max output frequency (E1-04) O O O — 4 Output Voltage Bias Motor rated voltage (E1-05). O – − — 7 Overtorque/Undertorque Detection Level Open Loop Vector: Motor rated torque V/f control:
Drive rated current O O O — B PID Feedback 10V = 100% O O O — C PID Set Point 10V = 100% O O O — E Motor Temperature (PTC input) 10 V = 100.00% Determined by L1-03 and L1-04. O O O — F Not used / Pass-through mode – O O O — 10 FWD Torque Limit Motor rated torque − O − — 11 REV Torque Limit Motor rated torque − O − — 12 Regenerative Torque Limit Motor rated torque − O − — 15 FWD/REV Torque Limit Motor rated torque − O − — 16 Differential PID Feedback 10 V = 100% O O O — No. Name Description Range Def. Control Mode Addr. Hex Pg. V/f O LV P M H4: Multi-Function Analog Outputs Use H4 parameters to configure the multi-function analog output terminals.
H4-01 Multi-Function Analog Output Terminal AM) Selects the data to be output through multi- function analog output terminal AM. Set the desired monitor parameter to the digits available in U-. For example, enter “103” for U1-03. When using this terminal in trough mode or when not using it at all, set “000” or “031”. 000 to 999 102 A A A 41D — H4-02 Multi-Function Analog Output Terminal AM Gain Sets terminal AM output level when selected monitor is at 100%. Maximum output voltage is 10 V. -999.9 to 999.9 100.0 % S S S 41E —