omron — L: Protection Function

B.2 Parameter Table Parameter List B OYMC TOEP C71060622-01-OY V1000 User Manual 347 No. Name Description Range Def. Control Mode Addr. Hex Pg. V/f O LV P M L7: Torque Limit Use L7 parameters to configure the torque limit function. L7-01 Forward Torque Limit Sets the torque limit value as a percentage of the motor rated torque. Four individual quadrants can be set.

output torque positive torque L7-01 L7-04 motor regeneration r/min REV FWD regeneration L7-03 L7-02 negative torque 0 to 300 200% − A − 4A7 — L7-02 Reverse Torque Limit 0 to 300 200% − A − 4A8 — L7-03 Forward Regenerative Torque Limit 0 to 300 200% − A − 4A9 — L7-04 Reverse Regenerative Torque Limit 0 to 300 200% − A − 4AA — L7-06 Torque Limit Integral Time Constant Sets the integral time constant for the torque limit. 5 to 10000 200 ms − A − 4AC — L7-07 Torque Limit Control Method Selection during Accel/Decel Selects the method of torque limit control during accel/decel. 0: Proportional Control (change to integral controls at fixed speeds).

Use this setting when acceleration to the desired speed has priority over torque limitation. 1: Integral Control. Use this setting if the torque limitation has priority. When torque limit is applied to the motor, accel/decel time may increase and motor speed may not meet the speed reference. 0, 1 0 − A − 4C9 — L8: Hardware Protection Use L8 parameters to configure hardware protection functions. L8-01 Internal Dynamic Braking Resistor Protection Selection (ERF type) Selects the Braking resistor when using a 3% duty cycle heatsink mounted OYMC braking resistor. This parameter does not enable or disable the braking transistor of the drive. 0: Resistor overheat protection disabled 1:

Resistor overheat protection enabled 0,1 0 A A A 4AD — L8-02 Overheat Alarm Level When the heatsink temperature exceeds the value set in this parameter, an Overheat Alarm (OH) will occur. 50 to 130 A A A 4AE — regeneration regeneration