B.2 Parameter Table Values shown here are for 200 V class drives. Double the value when using a 400 V class drive. Parameter setting value is not reset to the default value during drive initialization, A1-03 = 1110, 2220, 3330. Setting value 2 is not available A1-02 = 5-PM OLV Control. When enabled, the drive stops accelerating when it exceeds the value of L3-02, Stall Prevention Level. The drive decelerates after 100 ms and begins accelerating again after restoring the current level. Use caution when working with regenerative loads as motor speed can exceed the frequency reference during overvoltage suppression function operation.

Set to "Disable" when motor speed needs to accurately match the frequency reference, and also when using a braking resistor. An OV fault may still occur even when this function is enabled if there is a sudden increase in the regenerative load. The setting range depends on the control mode set in A1-02. For PM OLV Control the setting range is 0 to 2. Parameter value is changed if E2-11 is manually changed or changed by Auto-Tuning. The default value is 0 for all 200 V Single-Phase drives. Default setting value is dependent on parameter o2-04, Drive Unit Selection and C6-01, Drive Duty Selection. ◆ n:

Advanced Performance Set-Up The n parameters are used to adjust more advanced performance characteristics such as hunting prevention, speed feedback detection, high-slip braking and R1 online tuning. 350 OYMC TOEP C71060622-01-OY V1000 User Manual No. Name Description Range Def. Control Mode Addr. Hex Pg. V/f O LV P M n1: Hunting Prevention Use n1 parameters to configure hunting prevention operation. n1-01 Hunting Prevention Selection If the motor vibrates while lightly loaded, Hunting Prevention may reduce the vibration. 0: Disabled 1: Enabled When quick response is needed disable Hunting Prevention.

0,1 1 A − − 580 — n1-02 Hunting Prevention Gain Setting Sets the gain for the Hunting Prevention Function. If the motor vibrates while lightly loaded and n1-01 = 1, increase the gain by 0.1 until vibration ceases. If the motor stalls while n1-01 = 1, decrease the gain by 0.1 until the stalling ceases. 0.00 to 2.50 1.00 A − − 581 — n1-03 Hunting Prevention Time Constant Sets the time constant used for hunting prevention. 0 to 500 A − − 582 — n1-05 Hunting Prevention Gain while in Reverse Sets the gain used for Hunting Prevention. When set to 0, the gain n1-02 is used for operation in reverse direction. 0.00 to 2.50 0.00 A − − 530 —