B.2 Parameter Table Parameter List B OYMC TOEP C71060622-01-OY V1000 User Manual 361 No. Name Description Analog Output Level Unit Control Mode Addr. Hex V/f O LV P M U1-05 Motor Speed Displays the motor speed feedback. Display units are determined by o1-03. 10 V: Maximum speed 0.01 Hz – A A 44 U1-06 Output Voltage Reference Displays the output voltage. 10 V: 200 Vrms (400 Vrms) 0.1 V A A A 45 U1-07 DC Bus Voltage Displays the DC bus voltage. 10 V: 400 V (800 V) 1 V A A A 46 U1-08 Output Power Displays the output voltage (this value is determined internally). 10 V: Drive capacity (kW) (max.
motor capacity allowed) A A A 47 U1-09 Torque Reference Monitor of internal torque reference value for Open Loop Vector (OLV) control 10 V: Motor rated torque – – A – U1-10 Input Terminal Status Displays the input terminal status. U1-10=0000000 1: Digital input 1 (terminal S1) enabled 1: Digital input 2 (terminal S2) enabled 1: Digital input 3 (terminal S3) enabled 1: Digital input 4 (terminal S4) enabled 1: Digital input 5 (terminal S5) enabled 1: Digital input 6 (terminal S6) enabled No output signal available – A A A 49