omron — Default Settings Determined by Drive Capacity (o2-04) and ND/HD Selection (C6-01)

B.2 Parameter Table Table B.7 Three-Phase 400 V Class Drives Default Settings by Drive Capacity and ND/HD Setting Parameter List B OYMC TOEP C71060622-01-OY V1000 User Manual 379 No.

Description Unit Default Settings − Model VZA† − 40P2 40P4 40P7 41P5 C6-01 Normal/Heavy Duty − HD ND HD ND HD ND HD ND o2-04 Drive Unit Selection Hex 91 92 93 94 E2-11 (E4-11, T1-02) Motor rated power kW 0.2 0.4 0.4 0.75 0.75 1.5 1.5 2.2 b3-06 Speed Search current 1 − 1.0 1.0 0.5 0.5 0.5 0.5 0.5 0.5 b8-04 Energy saving coefficient − 713.8 576.4 576.4 447.4 447.4 338.8 338.8 313.6 C6-02 Carrier frequency − 3 7 3 7 3 7 3 7 E2-01 (E4-01, T1-04) Motor rated current A 0.6 1 1 1.6 1.6 3.1 3.1 4.2 E2-02 (E4-02) Motor rated slip Hz 2.5 2.9 2.9 2.6 2.6 2.5 2.5 3 E2-03 (E4-03) Motor no load current A 0.4 0.6 0.6 0.8 0.8 1.4 1.4 1.5 E2-05 (E4-05) Motor line-to-line resistance Ω 83.94 38.198 38.198 22.459 22.459 10.1 10.1 6.495 E2-06 (E4-06) Motor leakage inductance % 21.9 18.2 18.2 14.3 14.3 18.3 18.3 18.7 E2-10 (E4-10) Motor Iron Loss W 12 14 14 26 26 53 53 77 E5-01 Motor Code hex FFFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF L2-02 Momentary power loss ride-through time s 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 L2-03 Momentary power loss base block time s 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.5 L2-04 Momentary power loss voltage recovery time s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 L2-05 UV detection voltage V dc 380 380 380 380 380 380 380 380 L3-24 Motor acceleration time s 0.178 0.178 0.178 0.142 0.142 0.166 0.166 0.145 L8-02 Overheat alarm level °C 110 110 110 110 110 110 90 90 L8-09 Ground fault selection − 0 0 0 0 0 0 0 0 L8-35 Installation Method Sel.

− 0 0 0 0 0 0 0 0 L8-38 Carrier frequency reduction selection − 1 1 1 1 1 1 1 1 n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 10 10 10