omron — Default Settings Determined by Drive Capacity (o2-04) and ND/HD Selection (C6-01)

B.2 Parameter Table 380 OYMC TOEP C71060622-01-OY V1000 User Manual No. Description Unit Setting Range − Model VZA† − 42P2 43P0 44P0 45P5 C6-01 Normal/Heavy Duty Sel.

− HD ND HD ND HD ND HD ND o2-04 Drive Unit Selection − 95 96 97 99 E2-11 (E4-11, T1-02) Motor rated power kW 2.2 3.0 3.0 3.7 4.0 5.5 5.5 7.5 b3-06 Speed Search current 1 − 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 b8-04 Energy saving coefficient − 313.6 265.7 265.7 245.8 245.8 189.5 189.5 145.38 C6-02 Carrier frequency − 3 7 3 7 3 7 3 7 E2-01 (E4-01, T1-04) Motor rated current A 4.2 5.7 5.7 7 7 9.8 9.8 13.38 E2-02 (E4-02) Motor rated slip Hz 3 2.7 2.7 2.7 2.7 1.5 1.5 1.3 E2-03 (E4-03) Motor no load current A 1.5 1.9 1.9 2.3 2.3 2.6 2.6 4.0 E2-05 (E4-05) Motor line-to-line resistance Ω 6.495 4.360 4.360 3.333 3.333 1.595 1.595 1.152 E2-06 (E4-06) Motor leakage inductance % 18.7 19 19 19.3 19.3 18.2 18.2 15.5 E2-10 (E4-10) Motor Iron Loss W 77 105 105 130 130 193 193 263 E5-01 Motor Code hex FFFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF L2-02 Momentary power loss ride-through time s 0.5 0.5 0.5 0.5 0.5 0.5 0.8 0.8 L2-03 Momentary power loss base block time s 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.8 L2-04 Momentary power loss voltage recovery time s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 L2-05 UV detection voltage V dc 380 380 380 380 380 380 380 380 L3-24 Motor acceleration time s 0.145 0.145 0.145 0.154 0.154 0.154 0.168 0.175 L8-02 Overheat alarm level °C 100 100 100 100 100 100 110 110 L8-09 Ground fault selection − 0 0 0 0 0 0 1 1 L8-35 Installation Method Sel.

− 0 0 0 0 0 0 2 2 L8-38 Carrier frequency reduction selection − 1 1 1 1 1 1 2 2 n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 10 10 10