ZMM-Sliven C8C CU 325 — ZMM-Sliven C8C CU 325 Universal Lathe Machine Manual PDF

7.4 MAINTENANCE Warning: Access to electric cabinet is only admitted to qualified electrician or authorized by the owner person duly instructed for safety works with high voltage. Electric cabinet checks and repair works may be only performed after disconnecting the power supply from electric cabinet main disconnector QS 0 , and after following tests for lack of voltage. 7.4.1 CHECKS For safety operation with the machine following periodical checks must be observed:

Machine neutral (ground) in compliance with local norms for electric safety and if do not confirm take measures to eliminate the cause before machine start; Connection condition of all wires and cables and if find loose must be tighten; The condition and function of micro switch interlock on electric cabinet door ( SQ 1 ), on chuck guard ( SQ 3 ), on clutch ( SQ 4 ), on quadrant compartment door ( SQ 5 ) and both emergency stop pushbuttons (red mushroom) ( SВ 0 ) and ( SВ 5 ). C:\Users\ELENA\Desktop\UL_C8C_325_ENG.doc 55/67