C:\Users\ELENA\Desktop\UL_C8C_325_ENG.doc 58/67 Variations No Object of testing Di agram T est apparatus Test instructions permissible measured G7 Parallelism of tailstock quill axis with carriage movement. а) in horizontal plane b) in vertical plane Dial indicator according DIN 879 Bring dial indicator into contact with retracted and locked tailstock quill at c. Advance quill through 100mm and re-lock. Traverse carriage to d. Measure at position с, then at d. а) 0.015mm by 100mm directed towards tool point. b) 0.02mm by 100mm directed upwards. а) ......mm b).......mm G8 Parallelism of mounting taper in tailstock with carriage movement.а.
а) in horizontal plane b) in vertical plane Dial indicator according DIN 879. Test mandrel with mounting taper Test mandrel in retracted and locked tailstock quill. Bring dial indicator stylus into contact at c and traverse carriage along test mandrel. а) 0.03mm by 300mm directed towards tool point. b) 0.03mm by 300mm directed upwards а) ......mm b) .....mm G9 Equidistance of headstock and tailstock centers above reference plane. Dial indicator according DIN 879. Test mandrel mounted between centers. Tailstock and tailstock quill locked. Bring dial indicator into contact with top generatrix. Measure at both ends of the mandrel.
l 0.04mm (Tailstock center higher) ..........mm G10 Parallelism of spindle axis with longitudinal movement of upper slide. Dial indicator according DIN 879. Test mandrel with mounting taper Align upper slide guides parallel with spindle axis in the horizontal plane. Lock the carriage. Mount test mandrel in the internal taper and bring to mid-way position of run-out. Traverse upper slide with dial indicator attached thereto, the travel provided. 0.04mm by 300mm ..........mm G11 Squareness of spindle axis to movement of cross slide. Dial indicator according DIN 879. Test plate or straightedge fixed to spindle. Dial indicator mounted on cross slide. Test plate or straightedge fixed to spindle..
Traverse cross slide through .....……mm 0.02.mm by 300mm Error in the direction ≥ 90º .....…..mm G12 Spindle axial run out. Dial indicator according DIN 879. Steel ball according to DIN 5401 Bring dial indicator into contact with steel ball in center of lead screw. Using lead screw traverse carriage in both directions. This measurement may be disregarded if the practical testing P3 (working accuracy) is carried out. 0.015mm in each direction ......….mm G13 Measurement of pitch accuracy. а) generated by lead screw movement b) measured on lead screw а) Dial indicator according DIN 879. and master lead screw.
b) Precision measuring instrument to choice (use nut or nut segment) а) Mount master lead screw between centers and apply dial indicator to flank. b)Alternatively to measurement a) a test diagram traced by the lead screw when not installed may be presented. а) and b) 0.04mm by 300mm L up to 2000mm measured at any point. If the turning length exceeds 2000mm, the permissible variation is to be increased by 0.005mm for each additional 1000mm, but without exceeding a maximum permissible variation of 0.05mm by 300mm. Local tolerance: 0.015mm by 60mm measured at any point. а)......….. b).....….. ........…..