Delta Electronics AH — 9.2.1. AHxxEMC-5A

Chapter 9 Troubleshooting 9_ 9-19 Error code Description CPU Status LED indicator status ERROR BUS FAULT 16#2121 External interrupt service routine 245 does not exist. Stop Blinking Keep 16#2122 External interrupt service routine 246 does not exist. Stop Blinking Keep 16#2123 External interrupt service routine 247 does not exist. Stop Blinking Keep 16#2124 External interrupt service routine 248 does not exist. Stop Blinking Keep 16#2125 External interrupt service routine 249 does not exist. Stop Blinking Keep 16#2126 External interrupt service routine 250 does not exist. Stop Blinking Keep 16#2127 External interrupt service routine 251 does not exist.

Stop Blinking Keep 16#2128 An action in a sequential function chart is incorrectly assigned qualifiers related to time. Stop Blinking Keep 16#2129 The modifier R is assigned to an action in a sequential function chart incorrectly. Stop Blinking Keep 16#3040 Data in the E-CAM exceeds the range or does not exist. Continue Keep Keep 16#3100 Input parameters exceed the available setting range. Continue Blinking Keep 16#3102 An error occurs in a sub-function block inside the function block. Continue Blinking Keep 16#3103 The distance between the detecting sensors used for identifying exeptional bags is a negative value.

Continue Blinking Keep 16#3104 Phasing is executed again before the previous phasing is completed. Continue Blinking Keep 16#3105 Superimposing is executed again before the previous superimposing is completed. Continue Blinking Keep 16#3106 Chain position compensation is triggered before the previous compensation is completed. Continue Blinking Keep 16#3107 Film axis position compensation is triggered before the previous compensation is completed. Continue Blinking Keep 16#3108 Knife position compensation is triggered before the previous compensation is completed. Continue Blinking Keep 16#3400 Motion axis number is incorrect.

Continue Keep Keep 16#3401 SDO Data Type setting error (0~199) Continue Keep Keep 16#3404 The number of the counting channel exceeds the available setting range. Continue Keep Keep 16#3405 A negative value is given to Velocity. Continue Blinking Keep 16#340A Homing mode setting error. Continue Blinking Keep 16#340B Target distance is 0. Continue Blinking Keep 16#3410 User unit setting error; or the output pulse type setting error. Continue Blinking Keep 16#3411 Velocity factor overrides setting error. Continue Blinking Keep 16#3414 Pulse type setting error in DFB HCnt. _ Continue Keep Keep