HP — DISASSEMBLE SOLENOID DRIVE STARTER

Starter/Starter 6. Test for open circuits by touching probes to switch terminal (A) and to field coil terminal (B). There should be continuity. M37153 -UN-25JAN90 M98,2060K,36 -19-05NOV85 7. Touch probes to switch terminal (A) and to solenoid body (C). There should be continuity. If the solenoid fails any of the tests, it is defective and must be replaced. M37154 -UN-25JAN90 M98,2060K,37 -19-05NOV85 8. Remove two screws (A) and two thru-bolts (B). M37121 -UN-25JAN90 M98,2060K,38 -19-05NOV85 CTM2 (19APR90) 60-16 16, 18, 20 & 24HP Onan Engines AllTractorManuals.com 130495 NOTE: Make a mark across front bracket, field coil, and end cap to align parts in assembly. 9. Remove end cap.

Remove thrust washers (A) which may stick on end cap or around armature shaft. -UN-25JAN90 Inspect bushing in end cap for excessive wear. Replace end cap assembly if cap is bent or deformed, or if bushing is worn. M37122 M98,2060K,39 -19-05NOV85 60 16