Kendrion Kuhnke Automation GmbH CAM Creator This column shows the number of enabled cam tracks which you can set under Control/Options/Module/CAM, see 7.4.4.3 This column allows you to pick one of the operating models, i.e. 'Time‘ (time cam) or 'Distance‘. • Time cams enable the use of cams with constant times which solely depend on the triggering edge. o The application currently supports 5 time cams per cam program o Set the starting time and duty cycle, in [ms], e.g. start after 20 ticks for 500 ms cam time. • Distance cams: Enter the starting and end time in ticks or angular degrees (depends on setting) Used to show/set the start and end of CAM 1.
Kuhnke FIO CAM Control ( E 808 GB ) 29 11/10/2017 NOTE Online Change You may change the cams during operation. This requires you to disable the speed change-over first, see 7.4.4.5 Define a default program to be able to make online changes to any of your programs. NOTE Time cam The application currently supports 5 time cams per cam program NOTE The import utility expects and Excel sheet with the following tabs, e.g. Assuming you previously exported the cam table, you can save it as an Excel worksheet, open another Excel worksheet and import it to FIOCAM Creator. Assuming you did not export a cam table before, the following prompt will pop up when you run Excel: