4. Motion Control Instructions 4.6.34. MOVF_R Explanation of the instruction: MOVF_R is used for sending one 32-bit floating number to multiple target registers. When EN is on, the content of S1 is sent to the zone with D as the starting register and the data length is specified by S2. When the data length S2 is larger than maximum 64, it is counted as 64. And the part above 64 is invalid. Explanation of input and output parameter of the instruction: Note: This instruction can be used for multi-point transmission of the floating point only. For detailed application, please refer to the example on MOVF instruction.
DVP-MC operating manual 4-137 API Move floating number to multiple registers Controller MOVF R 161 _ 10MC11T Parameter Data Available Explanation name type device EN “MOVF R” is executed as “EN” turns on. _ BOOL M,I,Q, constant S1 The source where the data comes from. REAL Constant,D S2 The length of the transmitted zone, the max value for S2 is 64. UINT Constant,D D The starting one of the target registers REAL D