Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk UD3 Series Bi-directional Rotary Solenoid * By using a cooling surface 150 cm 2 , the permissible duty cycle can be extended up to 1.7x normal rating M A = Initial torque M E = End torque (5 ° before end of rotary angle) Coil terminals: Flying leads Weight: appr. 300 g Dyn. moment of inertia (rotational mass): appr. 0.7 10 --6 kg m 2 Time constant: appr. 2.5–12 ms For a nominal voltage of 205 V DC (connected to 230 V AC with Si-bridge rectifier) the torques will be the same as for our rotary solenoid range with a nominal voltage amounting to 205 V DC provided their duty cycles are the same.
The duty cycles available may differ from those of the 205 V DC range. Document RSU300/12 Revision 00 2 Ш4 h9 Ш4 h9 M3 Ш25 Ш35 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
Voltage rati ng V DC 24 205 V DC V oltage rating ED* LK % 100 38 24 15 4,4 100 39 22 14 5 % ED* LK Current ratin g mA 250 580 870 1.360 4.280 27 67 110 175 407 mA C urrent rating Nominal res istance 97,2 41,6 27,6 17,6 5,6 7.580 3.065 1.848 1.172 504 Nomin al resistance UD 32, 25° MA Ncm 1,15 2,10 2,45 3,50 3,30 4,10 4,25 4,80 6,90 6,30 1,00 2,00 2,10 3,20 3,20 4,00 4,10 4,70 5,90 5,90 Ncm MA UD 32, 25° ME Ncm Ncm ME UD 33, 35° MA Ncm 0,95 1,85 2,20 3,35 3,00 3,80 3,75 4,30 6,40 4,90 0,80 1,70 2,00 2,80 2,65 3,60 3,60 4,15 5,30 4,80 Ncm MA UD 33, 35° ME Ncm Ncm ME UD 34, 45° MA Ncm 0,65 1,60 1,80 2,95 2,60 3,40 3,40 3,80 5,60 4,30 0,54 1,40 1,50 2,60 2,30 3,20 3,10 3,80 4,70 4,25 Ncm MA UD 34, 45° ME Ncm Ncm ME UD 36, 65° MA Ncm 0,43 1,35 1,10 2,40 1,50 2,85 2,20 3,30 4,40 3,70 0,35 1,20 0,88 2,20 1,40 2,70 2,05 3,20 3,50 3,60 Ncm MA UD 36, 65° ME Ncm Ncm ME UD 39, 95° MA Ncm 0,18 1,20 0,57 2,10 0,90 2,40 1,35 2,50 2,50 2,50 0,14 1,05 0,45 1,95 0,80 2,30 1,20 2,40 2,10 2,50 Ncm MA UD 39, 95° ME Ncm Ncm ME 3 15±0,5 3 15±0,5
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk UD3 Series Ordering Information Rotary solenoid Order specifications Angular travel 25 ° 35 ° 45 ° 65 ° 95 ° Shaft design Flying leads (20 cm standard length) Coil terminals Nominal voltage Standard voltage (connected to 230 V AC with Si-bridge rectifier) Perm. duty cycle under air cooled conditions (LK) Insulation class: B (max. permissible temperature = 130 ° C) Test voltage:
2500 V (eff) Available Shaft design BOO Document RSU300/22 Revision 00 2 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. UD 3 4 -BOO- - F - 24 V DC 100 % ED UD 3 2 3 4 6 9 BOO F 24 205 100 % ED