Step 2 — Set Up Hardware (USB) 1 HS-21 Handheld Reader FIS-HS21-000XG HS-41X Handheld Reader FIS-HS41X-000XG 2 USB Cable, 6’ Straight 61-000224-01 USB Cable, 8’ Coiled 61-000224-02 1 Default to USB (HID) Save Settings Test Symbol (ABCDEFGHIJKLMNOP) 1. Click the HS-21/HS-41X button and then click OK . If you do not want to make this selection every time you start ESP , uncheck “Show this dialog at startup”. If you need to select another model later, click Switch Model at the top of the screen. Note: You can also type a name of your choice in the Description text field and click OK . 2. Click Yes when this dialog appears: Note: The USB interface draws its power from the host.

USB Hardware 2 When you start ESP , the following menu will appear: Step 4 — Select Model USB Installation To power on the reader, plug the USB cable into the reader’s handle and into the host’s USB port. After several seconds, the reader will beep twice and the LED will turn off. The reader will now be ready to use. Important: If you use a USB hub, be sure that it is a powered hub. Hardware for USB USB Hardware 1. HS-21/HS-41X Handheld Reader 2. USB cable RS-232 Hardware 1. HS-21/HS-41X Handheld Reader 2. RS-232 Cable 3.

RS-232 Power Supply Detaching the Cable The reader can be converted from USB to RS-232 or from RS-232 to USB by changing the cable and scanning the appropriate communications programming symbol below. To detach the USB or RS-232 cable from the reader, press a paper clip into the hole on the side of the Save Settings USB Interface RS-232 Interface ESP Software is Omron Microscan’s configuration and testing software. Use ESP to set up your HS-21 and HS-41X Handheld Reader. ESP can be found on the Omron Microscan Tools Drive that is packaged with the reader. Note:

ESP can also be installed from the Download Center at Step 1 — Check Required Hardware The HS-21/HS-41X is shipped with one of the following cables: • Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) 1. Follow the prompts to install ESP from the Tools Drive . 2. Click on the ESP icon to run the program. • 800 x 600 256 color display (1024 x 768 32-bit color recommended) Step 3 — Install ESP Minimum System Requirements • 233 MHz Pentium PC www.microscan.com .

• Internet Explorer 6.0 or higher 8’ RS-232 Coiled Cable • 128 MB RAM or greater • 160 MB free disk space 6’ USB Straight Cable P/N 83-110003 Rev A Step 2 — Set Up Hardware (RS-232) 1 HS-21 Handheld Reader FIS-HS21-000XG HS-41X Handheld Reader FIS-HS41X-000XG 3 1 Save Settings Test Symbol (ABCDEFGHIJKLMNOP) 2 RS-232 Cable, 8’ Coiled 61-000224-03 RS-232 Power Supply, 8’ Coiled, U.S.

20-000335-02 RS-232 Power Supply, 8’ Coiled, Euro 20-000336-02 RS-232 Power Supply, 8’ Coiled, UK 20-000337-02 RS-232 Hardware 2 Quick Start Guide HS-21/HS-41X Handheld Reader RS-232 Installation To power on the reader, plug the RS-232 cable into the reader’s handle, plug the power supply into the AC outlet, plug the power supply cord into the barrel jack on the cable, and then connect the cable to the appropriate serial port on the host. The unit will beep twice and the LED will turn off. The reader will now be ready to use.

Hardware for RS-232 Reset to RS-232 Factory Defaults 3 1 HS-21 Handheld Reader FIS-HS21-000XG HS-41X Handheld Reader FIS-HS41X-000XG 2 USB Cable, 6’ Straight 61-000224-01 USB Cable, 8’ Coiled 61-000224-02 HS-21 Handheld Reader 1 HS-41X Handheld Reader FIS-HS21-000XG FIS-HS41X-000XG 2 RS-232 Cable, 8’ Coiled 61-000224-03 RS-232 Power Supply, 8’ Coiled, U.S. 3 RS-232 Power Supply, 8’ Coiled, Euro RS-232 Power Supply, 8’ Coiled, UK 20-000335-02 20-000336-02 20-000337-02

Стр. 1

The following modes are accessible by clicking the buttons in App Mode icons: • • • • • Communication, Read Cycle, Symbologies, and I/O Parameters. • to use Window of Interest for Near Field and Far Field. • and to send serial commands to the reader using text or macros. • Utilities button to show the tabbed interfaces for Device Control, Differences from Default, Firmware, and Advanced settings. For further details, see ESP Help in the dropdown Help menu or refer to the HS-21/HS-41X Handheld Reader User Manual .

Step 7 — Configure the Reader USB Once you have clicked Connect in the USB Select Device field, the CONNECTED message will appear in a green box in the status bar at the bottom right of the screen. You are now ready to configure the USB HS-21/HS-41X using ESP . RS-232 Once you have selected RS-232 settings and communications port and clicked Connect , the CONNECTED message will appear in a green box in the status bar at the bottom right of the screen. You are now ready to configure the RS-232 HS-21/HS-41X using ESP . Step 6 — Connect to ESP 1. Print and decode the USB Connect Mode symbol to ensure that you are in the correct communications mode.

Keep the printed symbol in a convenient place for future use. Click Next when you are finished. 2. You will then see your reader’s ID in the Select Device field. The Reader ID number should match the serial number next to the trigger under the optical head of the reader. Click Connect . Print and decode the RS-232 Connect Mode symbol and decode it with the reader to ensure that you are in the correct communications mode. Keep the printed symbol in a convenient place for future use. Be sure the correct communications port is selected. Click Next , and then Connect . • Send, No Save . Changes will be lost when power is re-applied to the reader. • Send and Save .

This activates all changes in current memory and saves to the reader for power-on. Step 8 — Save Changes in ESP 5. Right-click on the open screen and select Save to Reader to implement the command in the reader. Step 5 — Select Interface To make changes to a configuration setting: Click the Show Connect Symbol button. Click the Show Connect Symbol button. Copyright © 2019 Omron Microscan Systems, Inc. 1. Left-click on the + to expand the desired tree. 2. Double-click on the desired parameter and click once in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change, and click once on the setting. 4.

Left-click on the open screen to complete your selection. RS-232 USB Click the Show Connect Symbol button. Click the Show Connect Symbol button.