NERLITE Dark Field Illuminators Configuration Guide Hardware Required 1 3 12V.

1.4A (UNFUSED) POWER OUTPUT 1 2 2 Figure A Dark Field Series Illuminator with power supply Figure B Dark Field Series Illuminator with NL-200 and power supply P/N 83-230003-04 Rev B Part Number Description Continuous Current No Controller Required (Can Be Connected Directly to 24VDC) NL-22X Optional (Us Only If Intensity and/ Ethernet Control Is Required ed Connection Notes Reference or Number (See the Connection Notes on the Second Page) NER-011609311 DF-50 Red Continuous, Non-Diffuse 69 mA Figure A Figure B 1 NER-011609321 DF-50 White Continuous, Non-Diffuse 120 mA Figure A Figure B 1 NER-011601520 DF-100-1 Red Continuous, Non-Diffuse 100 mA Figure A Figure B 1 NER-011601521 DF-100-1 Red Continuous, Diffuse 100 mA Figure A Figure B 1 NER-011600020 DF-150-1 Red Continuous, Non-Diffuse 100 mA Figure A Figure B 1 NER-011600021 DF-150-1 Red Continuous, Diffuse 100 mA Figure A Figure B 1 NER-011600208 DF-150-3 Red Continuous, Non-Diffuse 300 mA Figure A Figure B 1 NER-011603300 DF-200-1 Red Continuous, Diffuse 200 mA Figure A Figure B 1 Item Description Part Number 1 DF Series Illuminators NER-01160XXXX 2 Power Supply DSP60 24VDC 2.5A DIN Mount NER-011504100 3 NL-200 Current Controller Series 98-000152-0X - 12V + PO - PO + INP

Стр. 1

NERLITE Dark Field Illuminators Accessories Note: Certain lights require both channels of the NL-2XX Series Lighting Controller. Channel 1 and Channel 2 may have different current specifications on some models. Be sure each channel is set correctly as specified in this document. General Notes: 1. Those lights that do not require a controller require 24VDC +/- 1%. 2. The NL-2XX series controllers require 24 to 48VDC. 3. The cable on all flying lead models is terminated with three, five, or seven leads. Each lead is labeled. See “Connection Notes” for connection instructions. 4. For all models with M12 connectors, the connector is a 4 pin, male, M12 connector.

See “Connection Notes” or connector pin out and connection instructions. 5. All models with separate fan circuits must have 24VDC connected to the fan circuit at all times when the light is operating. 6. When operating in strobe mode at the maximum rated current, the maximum pulse width = 1mS and the maximum duty cycle = 6%. See the NL-2XX series controllers’ manual for pulse width and duty cycle limitations under various conditions. Connection Notes: 1. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller.

Connect the lead labeled “Shield” or “SHLD” to chassis ground. 2. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the nega- tive(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 3. Connect the lead labeled “V+1” to the positive(+) output terminal of channel 1 on an NL-2XX series controller.

Connect the lead labeled “GND1” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “V+2” to the positive(+) outpt terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “GND2” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Shield” to chassis ground 4. Connect the lead labeled “+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “-” to the negative(-) output terminal of the power supply or controller. Connect the cable’s braided shield to chassis ground. 5.

Connect the lead labeled “DOAL V+” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “DOAL GND” to the nega- tive(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “Ring V+” to the positive(+) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Ring GND” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply.

Connect the lead labeled “Shield” to chassis ground. 6. Connect the two leads labeled “RING 1, 2 V+” & “RING 3 V+” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled “RING 1, 2 -” & “RING 3 -” to the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground. 7. Connect Pin 1 of the M12-M connector to the positive(+) output terminal of the power supply or controller. Connect Pin 3 of the M12-M connector to the negative(-) output terminal of the power supply or controller. Connect the shell of the M12-M connector to chassis ground. Pins 2 and 4 are not used.

Copyright ©2019 Omron Microscan Systems, Inc. www.microscan.com AC Power Cord US NER-030028300 Power Cord For Power Supply AC Power Cord EU NER-030028400 Power Cord For Power Supply AC Power Cord UK NER-030028500 Power Cord For Power Supply