4201 Lien Rd. • Madison, WI 53704 Owner’s Manual — Phoenix Stackable CAM Pro Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Stackable CAM Pro offers all the great features of our proven CAM air movers, with the addition of an innovative stackable cabinet design. Featuring multiple contact points and interlocking side grills, the Phoenix Stackable CAM Pro can be stored safely and securely up to 4 units high, freeing up valuable space in your trucks and warehouses. The Stackable CAM Pro features class-leading airflow and efficiency.

Using a unique 1/3 horsepower motor design and proprietary blower technology, the Phoenix Stackables achieve 1050 CFM at over 2800 FPM with high static pressure, while using only 2.6 amps of electricity on high speed (2.0 amps on low). With it’s low amp draw and onboard GFCI, the Phoenix Stackable CAM Pro gives you maximum airflow on a circuit, allowing up to 4 CAMs on a standard 15 amp household circuit on high speed (or up to 6 on low speed). The Phoenix Stackable CAM housing is durable, washable, and chemical resistant. It features multiple operating positions allowing it to be aimed horizontally, vertically, or at 45°.

And, like all Phoenix air movers, the Stackable CAM Pro is ETL Listed, UL Certified. The Phoenix Stackable CAM Pro is also lightweight and properly balanced for easy handling. Other convenience features include a lighted cord for easier determination of power to the outlet and superior cord management for better handling, packing, and storage.

The Phoenix Stackable Centrifugal Air Mover Pro *PN 4030980 is pictured to demonstrate stackability • 2-Speed 1/3 Horsepower Motor 2.6 Amps on High Speed 2.0 Amps on Low Speed • Maximum Velocities 2800 FPM • Balanced Exhaust Airflow • Directional Airflow Horizontal, 45° Angle, 90° Angle • Durable, rugged, chemical resistant housing, fan wheel, and controls design. • Operator interface conveniently located for easy access, featuring: power indicator lamp and large three-position switch. • Ergonomic carry handle and power cord storage. • Non-marking, anti-skid, rubber feet.

• 4 CAMs on a circuit on high • 6 CAMs on a circuit on low • 20% more CFM/Amp than our current industry leading CAM • On-board duplex GFCI and circuit breaker • Stacks up to 4 units high Phoenix Stackable Centrifugal Air Mover Pro PN 4030990 Specifications subject to change without notice. TS-669 08/11 1 www.UsePhoenix.com • sales@UsePhoenix.com Toll-Free 1-800-533-7533

Стр. 1

Table of Contents Introduction ................................................................1 Centrifugal Air Mover Pro Features and Benefits ..............1 1. Safety Information .................................................2 2. Specifications ........................................................3 3. Power Requirements ..............................................3 3.1 Daisy-Chaining.................................................3 3.2 Recommended Use..........................................4 4. Operating Instructions ............................................4 5.

Operator Panel Features .........................................4 5.1 12 Amp Circuit Breaker....................................4 5.2 Power Indication Lamp.....................................4 5.3 3-Position Drying Selector Switch......................4 5.4 GFCI Protection................................................5 6. How to Stack .........................................................5 7. Maintenance ..........................................................5 7.1 Servicing.........................................................5 7.2 Cleaning..........................................................5 8. Replacement Parts and Optional Accessories ...........5 9.

Wiring Diagram ......................................................6 Warranty ...............................................................7 1 Safety Information When using any rotational electrical device basic precautions should always be followed, including the following: CAUTION! For general ventilating use only. Do not use in environments containing hazardous or explosive materials and vapors. • Do not operate the unit without the safety guards properly installed and secured. Do not operate the unit if the guards become damaged. Contact Therma-Stor for replacement parts. • Always replace the guards as originally installed after servicing or cleaning the product.

• Never place your face, hands, or other susceptible body parts in the air stream, inlets, or outlet of this device. • This fan is not a toy! Ensure children do not play with and do not have access to the equipment. Do not allow children to play with or stand near the unit or in its air flow. • Do not use this fan with any solid-state speed control device. • Do not operate unit with a cut or frayed power cord. Replace cord if it becomes damaged. • Handle with care. Do not drop or throw the unit. The unit can be damaged under harsh treatment. • Do not unplug the unit by pulling on the cord. Grasp the plug firmly and pull it out of the wall socket or power receptacle.

• Always use a grounded outlet. • Do not plug more than 9.3 amps total into the GFCI outlet. • Check GFCI protection before each use by pushing “test” button. If operating properly, “reset” button will pop out. • Never operate electrical equipment in standing water. • Never operate with the safety grills removed. Personal injury may result. • Do not stick your fingers or other objects through the safety grills. • Do not restrict airflow to the unit. This may cause the unit to overheat. • Unit should never be serviced or cleaned while it is plugged in. • Make sure the unit is secure, stable and safe from falling over or falling down before operating.

• Do not sit or stand on the unit or use as a step. • Do not leave device plugged in when not in use. • Indoor use only. Do not expose to water or rain (store indoors.) Serial No.__________________________________ Purchase Date_____________________________ Dealer’s Name_____________________________ Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix 4030990. 2 www.UsePhoenix.com • sales@UsePhoenix.com Toll-Free 1-800-533-7533

Стр. 2

• Use only as described in this manual. • Use only Manufacturer’s recommended attachments. Contact Therma-Stor for proper repair instructions. • Do not pull or carry it by the power cord, use cord as a handle, close doors on cord or pull cord around sharp edges. • Do not run or drive over cord. • Keep cord away from heated surfaces. • Do not handle power cord plug with wet hands. • Turn off all controls before unplugging. • Do not use when you are tired, distracted or under the influence of drugs, alcohol or medication. 2 Specifications Part No. 4030990 Power 115 VAC, 60 hz.

Operating 3 – 0°, 45°, 90° Positions Drive Motor 1 /3 Horsepower, 2-Speed Motor Thermal cut-off Protection Cord Length 20 Feet Airflow 2800 ft/min outlet velocity Warranty One Year - 100% parts and labor (all components) Current Draw 2.6 Amps High speed, 2.0 Amps Low speed LIRE ET CONSERVER CES INSTRUCTIONS • Risque de choc йlectrique Peut causer des blessures ou la mort. Dйbrancher toutes les alimentations en courant йlectrique а distance avant l’entretien ou le nettoyage. • Ne pas utiliser l’appareil avec un cordon d’alimentation coupй ou effilochй. • Ne pas dйbrancher l’appareil en tirant sur le cordon.

Tenir la fiche fermement et la tirer hors de la prise murale ou la prise d’alimentation йlectrique. • Toujours utiliser une prise mise а la terre. • Ne jamais utiliser l’йquipement йlectrique dans de l’eau stagnante. • Ne jamais utiliser sans les grilles de protection. Des blessures risquent d’en rйsulter. • Ne pas brancher plus de 8 ampиres au total au diffйrentiel. • Vйrifier la protection du diffйrentiel avant chaque utilisation en appuyant sur le bouton “ test “. Si l’appareil fonctionne correctement, le bouton “ reset “ ressort. • Ne pas passer les doigts ou d’autres objets dans les grilles de protection. • Ne pas diminuer le dйbit d’air arrivant jusqu’а l’appareil.

L’appareil risque de trop chauffer. • Ne pas s’asseoir ou se tenir debout sur l’appareil; ne pas l’utiliser comme йtagиre ou table. • Avant de laisser un appareil aйraulique axial sans surveillance, s’assurer que les enfants n’ont pas accиs а l’йquipement. Ne pas laisser les enfants jouer avec l’appareil ou а proximitй de l’appareil ou dans l’air qu’il projette. • Pour rйduire le risque d’incendie ou de choc йlectrique, ne pas utiliser ce ventilateur avec un dispositif de commande de vitesse а semi-conducteurs. Three Years - Only materials and workmanship of the housing are covered.

Dimensions Machine Shipping Width 17.25” 17.3” Height 20” Depth 19.4” Weight 27 lb 30 lb 3 Power Requirements 3.1 Daisy Chaining The Phoenix Centrifugal Air Mover draws 2.6 amps. The 12 amp, on-board circuit breaker will allow four (4) Phoenix Centrifugal Air Movers on one circuit. When daisy-chaining the Phoenix Centrifugal Air Mover, turn on one Phoenix Centrifugal Air Mover at a time to prevent excessive current inrush caused by four units starting at once. A ground fault in the Phoenix Centrifugal Air Mover Pro or anywhere on the circuit will cause the Phoenix Centrifugal Air Mover’s GFCI to trip. After rectifying the ground fault, reset the GFCI by pressing the reset button. 5 Figure 1:

Too many Centrifugal Air Movers daisy-chained 3 www.UsePhoenix.com • sales@UsePhoenix.com Toll-Free 1-800-533-7533

Стр. 3

3.2 Recommended Use Recommended use(s) of on-board duplex GFCI are shown. Note: Standard 115 VAC electrical outlets. IMP0RTANT: Total amperage of the Centrifugal Air Mover plus all devices plugged into the receptacle must not exceed 12 amps. The circuit breaker will not allow for loads in excess of 12 amps, although there is a time delay before the overloaded circuit is broken. 5.2 Power Indication Lamp The red, sealed, high intensity AC voltage power indication lamp allows operators to visually identify the operation status of several Phoenix Centrifugal Air Mover Pros at a distance, with a single glance.

The power indication lamp will remain lit when the AC power cord is plugged into a standard “powered” AC power outlet and the 3-Position drying selector switch is in either the HIGH or LOW operation position. The power indication lamp will remain unlit when the AC power cord is unplugged, the 3-Position drying selector switch in the OFF position, the on-board GFCI or 12 Amp circuit breaker is tripped, or the connected, standard AC wall outlet power has been turned off. 15 Amp Outlet 15 Amp Outlet 15 Amp Outlet Phoenix Phoenix Phoenix CAM CAM CAM Phoenix Phoenix Phoenix CAM CAM CAM Phoenix Phoenix CAM CAM Phoenix Phoenix 200 MAX Figure 2:

Duplex GFCI use CAM Phoenix Mini-Guardian 4 Operation Instructions The Phoenix Centrifugal Air Mover Pro is intended for use by water damage restoration, carpet cleaning, construction, and janitorial/sanitation professionals in general ventilating and structural surface drying applications. The Phoenix Centrifugal Air Mover Pro as packaged is ready to be put into service. Inspect the unit completely for any shipping damage. Place the unit on the ground. Check the GFCI to ensure it is not tripped. Plug the unit into a grounded outlet and select the drying mode. 5.3 3-Position Drying Selector Switch The Phoenix Centrifugal Air Mover Pro features a three- position switch - LOW–OFF–HIGH. 1.

Inspect the machine for damage and airflow obstructions prior to plugging it in or operating it. 2. Ensure the power switch is in the OFF (middle) position. 3. Place the machine into the desired position for operation. Ensure that the machine rests stable and secure and will not overturn. 4. Plug the power cord into a GFCI protected outlet. Do not use an extension cord in conjunction with the standard power cord. 5. Turn the unit on to the desired speed, high or low. CAUTION: The Phoenix Centrifugal Air Mover Pro consumes 2.6 Amps on high speed. Do not plug devices requiring more than 9.3 Amps of current into the duplex outlet.

12 Amp Circuit Breaker 5 Operator Panel Features 5.1 12 Amp Resettable Circuit Breaker The 12 AMP thermal response resettable circuit breaker protects the unit and devices connected to its duplex GFCI outlet. The circuit breaker is designed to sense the total current draw through the circuit. The circuit breaker “trips” when more than 12 amps of electrical current are drawn through the device’s power cord. Should an over-current condition occur, the Centrifugal Air Movers’ on-board circuit breaker trips thus preventing nuisance visits to a remote power junction box. To reset on-board breaker, remove over drawing equipment. Allow to cool for 10 minutes and reset breaker.

AC Indicator Lamp GFCI Outlet High Speed: “Ultra” Drying Power Stainless Steel Control Panel Low Speed: Quiet Operation Figure 3: Centrifugal Air Mover Pro Operator Panel 4 www.UsePhoenix.com • sales@UsePhoenix.com Toll-Free 1-800-533-7533