Chapter 3 Product Specifications 3_ User-defined Addresses Digital Input/Output Modules You can assign input devices and output devices to a digital input/output module through HWCONFIG in ISPSoft. The input devices should be within the range between X0.0 and X511.15 , and the output devices should be within the the default output devices are Y0.0~Y0.15. You can change the input device range from X0.0~X0.15 to X10.0~X10.15, range between Y0.0 and Y511.15 . Take AH16AP11R-5A for example. The default input devices are X0.0~X0.15, and and change the output device range from Y0.0~Y0.15 to Y20.0~Y20.15. The default input/output device range:
X0.0~X0.15, and Y0.0~Y0.15 The user-defined input/output device range: X10.0~X10.15, and Y20.0~Y20.15 3-11 10EN/15EN The input device range occupies 20 data registers and output device range 20 data registers. 10SCM The input device range occupies 18 data registers. 10DNET No input device and output device will be occupied. 10PFBS No input device and output device will be occupied. 10PFBM The input device range occupies 15 data registers. 10COPM The input device range occupies 2 data registers. 15SCM The input device range occupies 18 data registers.