Delta Electronics AH — 3.2.4 I/O Addressing of AH Motion CPU

AH Motion Controller – Hardware Manual Analog Input/Output Modules You can assign input registers and output registers to an analog input/output module through HWCONFIG in ISPSoft. The input registers and the output registers should be within the range between D0 and D65535 . Take AH06XA-5A for example. The original input registers are D0~D7, and the original output registers are D8~D11. You can change the input device range from D0~D7 to D50~D57, and change the output device range from D8~D11 to D100~D103.  The default input/output device range: D0~D7, and D8~D11 _3  The user-defined input/output device range:

D50~D57, and D100~D103 Temperature Measurement Modules You can assign input registers to a temperature measurement module through HWCONFIG in ISPSoft. The input registers should be within the range between D0 and D65535 . Take AH08TC-5A for example. The original input registers are D0~D15. You can change the input device range from D0~D15 to D60~D75.  The default input device range: D0~D151 3-12