1.7 CRANKSHAFT 1.7.2.3 Adjacent Journal Alignment When run-out on the adjacent journals is in opposite directions, the sum must not exceed 0.076 mm (0.003 in.) total indicator reading. When the high spots of run-out on the adjacent journals are in the same direction, the difference must not exceed 0.076 mm (0.003 in.) total indicator reading. 1.7.2.4 Journal Diameter Measurements Measure all of the main and connecting rod bearing journal diameters. See Figure 1-122. Figure 1-122 Dimensions of Crankshaft Journals Measure the journals at several places on the circumference so that taper, out-of-round and bearing clearances can be determined.
If the crankshaft is worn so that the maximum connecting rod or main bearing journal-to-bearing shell clearance (with new shells) exceeds 0.1270 mm (0.005 in.) (connecting rod journals) or 0.1422 mm (0.0056 in.) (main bearing journals), the crankshaft must be reground. Measurements of the crankshaft should be accurate to the nearest 0.0025 mm (0.0001 in.). Also, if the main bearing journal taper of a used crankshaft exceeds 0.0381 mm (0.0015 in.) or the out-of-round is greater than 0.0254 mm (0.001 in.) the crankshaft must be reground. Specifications for the crankshaft are listed in Table 1-22. (Rev. 2005) All information subject to change without notice.
1-140 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION