MAINTENANCE MAINTENANCE PROCEDURE CHECK, ADJUST TENSION OF AIR CONDITIONER COMPRESSOR BELT Checking Press the belt at a point midway between the drive pulley and compressor pulley with a finger force of approx. 58.8 N (6 kgf) and check that the deflection is 5 - 8 mm. Compressor pulley Drive pulley Adjusting 1. Loosen bolts (1) and (2). Bracket (4) holds the compressor in place. When bolts (1) and (2) are loosened, bracket (4) moves with the securing position of bolt (2) as a fulcrum. 9JH02656A 2. Loosen bolt (1) and bolts (2), then move compressor (3) to adjust. 3. When the position of the compressor is determined, tighten bolts (1) and (2) to hold it in position. 4.
Check each pulley for damage, wear of the V-groove, and wear of the V-belt. In particular, be sure to check that the V-belt is not touching the bottom of the V-groove. 9JH02657A 5. Replace belt if it has stretched, leaving no allowance for adjustment, or if there is a cut or crack on V-belt. 6. When the new V-belt is set, readjust it after operation for an hour. 257