Komatsu — Checks Before Starting

OPERATION Checks Before Starting Always check the items in this section before starting the engine each day. Drain Water And Sediment from Fuel Tank 1. Open the pump room door on the right side of the machine. 2. Set a container under drain hose (1) to catch the drained fuel. 3. Open drain valve (2) at the rear of the fuel tank and drain the water and sediment accumulated at the bottom of the tank together with the fuel. 4. When only clean fuel comes out, close drain valve (2). 5. Close the pump room door on the right side of the machine. Check for Water and Sediment in Water Separator, Drain Water 1. Open the pump room door on the right side of the machine.

The water separator forms one unit with fuel pre-filter (1). 2. It is possible to judge the water level and amount of sediment by looking through transparent cap (2). If there is any water or sediment collected at the bottom, set a container to catch the drain water under drain hose (3). 3. Loosen drain valve (4) and drain the water. 4. When fuel starts to drain from drain hose (3), tighten drain valve (4) immediately. On this machine, a sensor is installed to detect if water is accumulated in transparent cap (2). When the water separator monitor (5) lights up red on the machine monitor, it indicates that water is accumulated in transparent cap (2).

In this case also, use the procedure above to drain the water. Remark When only the water separator monitor lights up, it lights up in the position shown in the diagram on the right. If other monitors also light up the same time, the water separator monitor lights up at a different position. Remark If the water accumulated in transparent cap (2) freezes, the water separator monitor may not light up. After the engine is started, as the temperature around fuel pre-filter (1) increases, the frozen water will melt and the water separator monitor may suddenly light up. In cold areas, even if the water separator monitor does not light up, drain the water frequently.

If the water inside transparent cap (2) freezes, check that the frozen water has melted completely, then use the procedure above to drain the water. 2-116 PC200LC-8