MAINTENANCE Cleaning Outer Element Remark Before and after cleaning the element, do not leave or keep it in direct sunlight. 1. Open the rear door at the left side of the machine, remove four hooks (2), then remove cover (3). Remark Never remove the inner element (6). It will allow dirt to enter and cause failure of the engine. Do not use a screwdriver or other tool. 2. Hold the outer element (5), rock it lightly up and down and to the left and right, and rotate the element to the left and right to pull it out. 3. When the outer element (5) has been removed, check that the inner element has not come out of position and is not at an angle.
If it is at an angle, insert your hand and push it in straight. 4. After removing the outer element (5), cover the inner element (6) with a clean cloth or tape to prevent dirt or dust from entering. 5. Wipe off or brush off the dirt stuck to cover (3) and the inside of the air cleaner body (7). 6. Remove any dirt or dust that is accumulated to evacuator valve (4) installed to cover (3). Remark When cleaning the element, do not hit or beat it against anything. 7. Direct dry compressed air (less than 7 kgf/cm 2 (99.4 psi)) to the outer element from inside along its folds, then direct it from outside along its folds and again from inside. A.
Replace the outer element which has been cleaned six times repeatedly or used throughout a year. Replace the inner element at the same time. B. Replace both inner and outer elements when the air cleaner clogging monitor (1) lights up soon after installing the cleaned outer element even though it has not been cleaned six times. PC200LC-8 3-23