Komatsu — Attachment Removal

OPTIONS, ATTACHMENTS 6. After checking that the oil temperature is low, set the rotor of the stop valve installed to the inlet port on the side face of the arm and the outlet port piping to LOCK position (b). (a) FREE: Hydraulic oil flows (direction of arrow is parallel to long direction of arm). (b) LOCK: Hydraulic oil does not flow (direction of arrow is at right angles to long direction of arm). When setting the FREE or LOCK position of the stop valve rotor, remove bolt (2), turn over plate (1), then turn the rotor. After setting, install plate (1) again with bolt (2). 7. Remove the hoses on the attachment side. Install the plugs to the two outlets.

The plugs are used to prevent the attachment from incorrect operation caused by mixing in of foreign matter. After the plugs are correctly installed, store the attachment. 8. Pull out the mounting pins (two places), remove the attachment, then install the bucket. For details of the procedure for installing the bucket, see “BUCKET REPLACEMENT AND INVERSION” on page 2-171. 9. After installing the bucket, check the oil level in the hydraulic tank. 5-18 PC200LC-8