POWER TAKE-OFFS 4-17 E URO C ARGO E URO 4 - 5 Look at the example in Figure 4.7: − Maximum engine torque 600 Nm. − The standard operation of the PTO is 900 rpm. − The engine rpm must not exceed 1100 rpm. − The rpm must be determined for all of the overrun regulator slope. The slope of the curve for the overrun regulator depends on the particular use of the vehicle. For this reason, when stationary, it is generally sufficient for the overrun regulator to have a steep curve, whereas for the ”driving” mode, this might give rise to rapid changes in load, which may cause problems. Power is 1100 rpm and torque is equal to 600 Nm i.e.: P = (600Nm x 1100rpm)/9550 = 69KW = 94CV.
• The available rpm at 600 Nm can be calculated using a steeper overrun regulator (curve C; gradient 2CV/rpm): 1100 rpm - (94CV/2CV/rpm) = 1100 rpm - 47 rpm = 1053 rpm • The available rpm at 600 Nm can be calculated by using an intermediate overrun regulator (curve B; gradient 1CV/rpm): 1100rpm - (94CV/1CV/rpm) = 1100 rpm - 94 rpm = 1006 rpm • The available rpm at 600 Nm can be calculated by using a flat overrun regulator (curve A; gradient 0.65CV/rpm): 1100rpm - (94CV/0.65CV/rpm) = 1100 rpm - 145 rpm = 955 rpm So, based on the example above, the number of intermediate revs, Nres, should be set to 900 rpm. This wil then be activated automatically when the power take off mode is selected.
From the example, we see the influence of the overrun regulator. Depending on the usage, the chosen torque of 600 Nm is available up to 1055 rpm, 1005 rpm or 955 rpm. The same is true in reverse. When the engine torque, the intersection point X and the steepness of the overrun regulator are predetermined, it is possible to calculate the number of revs of the end speed. ! The maximum rpm N max is a theoretical value. This is the rpm at which the ECU reduces the injected amount of fuel at 0 mg/stroke. Considering that all engines, according to the rpm (engine hot and no load) need 20-30 mg/stroke of fuel to maintain the rpm, this theoretical value N max is never reached.
According to the slope of the overrun regulator, the rpm actually reached is 10-40 rpm lower. You are advised to define overrun ratio by means of practical tests if this is likely to effect the application. 4.6.4 Intermediate rpm regulator Maximum intermediate rpm regulator setting that can be achieved with SET+, N SET_max The maximum intermediate rpm regulator (CC) setting that can be achieved with SET+ (CC) can be configured. This limit is identical for all PTO modes (driving mode 0, PTO modes 1, 2 and 3). PTO management Print 603.93.431 Base - July 2006 Revi - June 2007