POWER TAKE-OFFS 4-18 E URO C ARGO E URO 4 - 5 Intermediate rpm regulator priority The maximum rpm N max (driving mode 0, PTO modes 1, 2 and 3) has a higher priority than the maximum rpm N SET_max which can be achieved with SET+ as well as the stored rpm N res . N max can be programmed according to the bodybuilders requirements under PTO modes 1, 2 and 3. The intermediate rpm N res stored under the respective modes must be either lower than or equal to the maximum rpm N SET_max which can be achieved with the SET+ button. TIP function The TIP function, i.e. brief pressure ( of the SET+/SET- buttons, is used to gradually change the intermediate rpm and speed regulator.
The intermediate rpm regulator will be activated at speed the speed regulator will be activated at speed > 25 km/h. The speed variation of the intermediate rpm regulator steps are equal to 20 rpm for tip, which corresponds to 1 km/h for the speed regulator. The intermediate rpm or speed value is modified continuously by pressing the SET+ and SET- buttons for more than 0.5s. The effective rpm and effective speed when the SET+ and SET- buttons are released and stored as the new value. The TIP with buttons SET+ and SET- can be deactivated. This configuration is valid for all PTO modes at the same time (driving mode 0, PTO modes 1, 2 and 3).
TIP function deactivation functionally limits the speed regulator. Consequently, this change should be carefully evaluated before being implemented. Note: This function is provided for the regulationof hydraulic units. Increasing/decreasing rpm with SET+/SET- The intermediate rpm regulator value can be changed by pressing the SET+/SET- buttons for more than 0.5s or when the TIP function is deactivated by a certain speed (engine rpm increase/decrease per second). The time interval for this change can be calculated using the following formula: Time required [s] = Rpm difference [rpm/s] / rpm increase per second [rpm/s /s] Example:
take the intermediate rpm from 800 rpm to 1800 rpm using the SET+ button. The difference in rpm is equal to 1000 rpm, consequently: − At a speed of 125 rpm/s, the time interval is 1000/125 = 8s − At a speed of 250 rpm/s, the time interval is 1000/250 = 4s − At a speed of 500 rpm/s, the time interval is 1000/500 = 2s − At a speed of 1000 rpm/s, the time interval is 1000/1000 = 1s Activating/deactivating the accelerator pedal The accelerator pedal is always active in normal driving mode (PTO mode 0). The accelerator pedal can be deactivated in PTO modes 1, 2 or 3. In this case, PTO engine regulation will ignore the accelerator pedal.
If the accelerator pedal is active, the engine rpm can be increased by means of the pedal to the maximum rpm N max valid at the time. PTO management Base - July 2006 Revi - June 2007 Print 603.93.431