Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

POWER TAKE-OFFS 4-22 E URO C ARGO E URO 4 - 5 Adjustment of the minimum number of revs that can be reached with SET-, NSET_min The idling speed must only be set when the engine is warm. There are three stages in the process: 1) Idle running actuation The engine must operate at idling speed. − Actuate the service brake (until the end of adjustment) − Press the Resume button for more than 3 seconds (and then release) Immediately afterwards, the idling speed reduces automatically to the minimum value. 2) Modifying the minimum idling speed It is possible to regulate the idling speed by intervals of 20 min-1 using the SET+ or SET- buttons.

3) Recording the minimum idling speed (in revs) The speed is stored by pressing the CC Resume button again (for more than 3 seconds). ! The idling speed can only be adjusted in the various PTO power take off modes which are used to activate the CC buttons, otherwise the regulation of the number of intermediate revs is disengaged using the brake or clutch. The adjusted interval for the idling speed, set at the factory, is 100 rpm. IVECO Service can increase this interval to 200 rpm. The adjusted interval for the idling speed is identical for all power take off modes (drive mode 0 or power take off modes 1, 2 and 3).

Influence of the retarder on the intermediate number of revs The engagement of the retarder causes the intermediate number of revs regulator to be deactivated (this has the identical effect as pressing the CC Off button). All the CC buttons (CC Resume / SET+ / SET-) are ignored when the retarder is engaged. ! The regulator for the intermediate number of revs will not be deactivated if the retarder is engaged when the following combination occurs: ”intermediate number of revs deactivated through either the brake or clutch = deactivated” and the ”intermediate number of revs is lower than 900 rpm”.

When the retarder is activated, the engine speed is instead lowered to the idling speed and all the CC buttons (CC Resume / SET+ / SET-) are ignored. Once the retarder has then been disengaged, the original number of revs will be restored. PTO management Base - July 2006 Revi - June 2007 Print 603.93.431