Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

POWER TAKE-OFFS 4-26 E URO C ARGO E URO 4 - 5 Isochronous control of engine rate For power take-offs where it is necessary to set the values for N res and N SET_max and N SET_min which are different from those already established (e.g. to avoid overrunning of the pump) the system permits the resetting of the control unit for the new values required. The operation is carried out at the IVECO Network Centers equipped with E.A.SY. test tools, providing indications below: D Type of vehicle; chassis No. D Type of engine; Serial No. D N res (rpm) required D N SET_max (rpm) required D N SET_min (rpm) required The system allows adjustment of N res up to N SET_max - 50 (rpm). Note:

The use of the MODUS station must take place after an upgrade is run using E.A.SY. software Isochronous control of engine rate Base - July 2006 Revi - June 2007 Print 603.93.431