CHASSIS MODIFICATIONS 2-69 E URO C ARGO E URO 4 - 5 Operations on the electrical system 2.21 Changes to the electrical system 2.21.1 General Information The vehicles operate on a 24v electric system for normal requirements and the chassis is an earth return. This acts as a current return wire between relevant components, such as battery and alternator. All component negative terminals are connected through the chassis in the absence of an insulated return wire. Installation of auxiliary equipment or circuits added by the bodybuilder must take into account the instructions given below. Depending on the complexity of the modification, suitable documentation (e.g.
electrical diagram) must be provided for inclusion with that relating to the vehicle. Use colours and/or codes for wires and connectors equal to those used on the original vehicle makes the installation more consistent and facilitates repair work. Note: For more detailed information on the vehicle’s electrical system, please refer to the specific Workshop Manuals. The vehicles are equipped with sophisticated electrical/electronic systems controlling their operation. Work on the system (e.g.
removing wiring harness, making additional circuits, replacing equipment, changing fuses, etc.) that is not done in conformity with IVECO instructions or is carried out by unskilled personnel can severely damage the systems (control units, wiring, sensors, etc.), jeopardizing safety and operation of the vehicle besides causing significant damage (e.g. short-circuiting with the risk of fire and destruction of the vehicle) that is not covered by warranty. ! It is absolutely prohibited to make any changes or connections to the line linking the ECU’s (CAN line), which cannot be tampered with, under any circumstances.
Any fault diagnosis or maintenance work can only be done by authorized personnel with IVECO approved equipment. ! Always disconnect the batteries before commencing any work on the electrical system. First disconnect the negative and then the positive power cable. Use fuses with the required capacity for their specific function. Never use fuses of higher capacity. Change them only after eliminating the problem with keys and ancilliaries disconnected. Restore the original conditions of the wiring (routing, guards, and binding, preventing the cable at all costs from coming into contact with metal surfaces of the structure that may impair its integrity).
Operations on the electrical system Print 603.93.431 Base - July 2006 Revi - June 2007