CHASSIS MODIFICATIONS 2-70 E URO C ARGO E URO 4 - 5 2.21.2 Modifying the electrical system Alternator, electrical/electronic components In order to protect the vehicle components, take the following precautionsat all times. Never disconnect the batteries from the system or open the main current switch when the engine is running. Never disconnect the connectors from the control units when the engine is running or when the control units are powered. Never power components interlocked by electronic modules with the rated voltage of the vehicle through wander cables. Control units equipped with metal sheathes have to be earthed through a screw or bolt unless otherwise specified.
Do not tow-start the vehicle. Do not start the engine without connecting the batteries permanently. Should it be necessary to quick charge the batteries, disconnect them from the vehicle circuit. Starting will have to be carried out only with the external battery trolley, ensuring correct polarity. Checking the earth connections As a general rule the original earth connections of the vehicle must not be changed. If it is necessary to move these connections or to implement further earth points use the existing holes on the chassis as far as possible and:
- Remove the paint, either by filing and/or using a suitable chemical product, on both the chassis side and terminal side, ensuring that the anaphoretic paint is completely removed from the chassis and a support surface is created with no indentations or ridges; - Apply appropriate high conductivity paint between the cable terminal and the metal surface. Connect the earth cables within 5 minutes from the application of the paint.Do not use the standardised (engine and chassis earth connection) points for the earth connections for control switches (e.g. sensors or low absorption devices). Figure 2.30 A B D C B C A --0 +0.5 4972 86686 4974 EARTH CONNECTIONS: A. EFFICIENT EARTH POINT B.
INEFFICIENT EARTH POINT WIRE ATTACHMENT: A. SCREW B. WIRE TERMINAL C. WASHER D. NUT WIRE CONNECTED TO EARTH Operations on the electrical system Base - July 2006 Revi - June 2007 Print 603.93.431