Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

CHASSIS MODIFICATIONS 2-71 E URO C ARGO E URO 4 - 5 The negative wires connected to the system earth points must be as short as possible and interconnected with a ”star” connection. Figure 2.31 2231 --0 +0.5 2603 2.21.3 Additional circuits These must be separated from the vehicle’s main circuit and protected with a fuse. Additional electric wires must be connected to the original electrical system with the same type of sealed connectors as the original ones. They must be protected with sheaths (not PVC) or ducted in corrugated pipes fixed with fasteners, shielded from impact and heat sources. The wires must be at minimum distances of:

- 150 mm from major heat sources (turbine, engine, exhaust manifold, ...) - 50 mm from containers of chemical agents (batteries, etc...) - 20 mm rom moving parts Take great care to prevent the wires rubbing against other components, especially against sharp edges on the bodywork. Wherever possible, wire routes must be secured with fasteners and dedicated clips, set close together (about 350 mm apart) to prevent sagging, making it possible (and obligatory) to route them in the same way after repairs/ fitting work. When the wires pass through holes or along the edges of panels, etc. they must be shielded with protective conduits (in addition to the corrugated piping).

It is forbidden to drill through the chassis for wire passages. Operations on the electrical system Print 603.93.431 Base - July 2006 Revi - June 2007