Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

CHASSIS MODIFICATIONS 2-72 E URO C ARGO E URO 4 - 5 The corrugated piping must protect the whole wire completely and connected to the rubber grommets on the terminals (with heat-shrink fasteners or tape). The clips on the corrugated pipe (when cut lengthwise) must not deform the pipe and the wires must not stray out of the piping or come into contact with sharp pipe edges. All (+) terminals for wires must be protected with rubber grommets, (hermetically sealed in zones exposed to atmospheric agents or where water collects). The wires must be attached to the terminals (both positive and negative) in such a way as to prevent slackening.

Tighten with a torque wrench where possible and using radial crimpers for multiple connections (to be avoided where possible). Where possible it is recommended that different runs are used between wires (looms) with high intensity absorption signals (e.g. electric motors, solenoid valves) and those with low intensity absorption signals (e.g. sensors) to avoid any interference between them. All should be kept as close as possible to the metal structure of the vehicle. When making chassis-tiltable cab connections, the position of the wire bundle must be checked with the cab both closed and open, in order to detect and put right any possible obstructions or stretching.

Use fuses and wires of suitable cross-section, depending on current levels, as shown in the table. The fuse must be installed as close as possible to the current drawing point. ! Table 2.18 1) For use periods longer than 30 seconds. According to the position as well as the temperature that might be registered inside the storage compartment choose fuses that can be charged up to 70% - 80% of their total maximum capacity. When grouping several wires together, remember that there will be a reduction in their intensity as compared to the rated value of a single cable due to reduced heat dissipation.

On vehicles where the engine is frequently started up, with power drawn off and limited engine speed (e.g., vehicles with cold storage), periodically charge the battery to keep it effective. Plug connections and terminals must be shielded and resistant to atmospheric agents, using the same type of components as on the original vehicle. Operations on the electrical system Base - July 2006 Revi - June 2007 Print 603.93.431 Max continuous current 1) (A) Wire cross-section (mm2) 4 0.5 10 1 20 2.5 25 4 35 6 50 10 70 16 90 25 120 35 150 50