107 Saving Energy with Frequency Converters Power Drive System (PDS) Driven Equipment Complete Drive Module (CDM) Mains & cabling Feeding section Auxilia- ries Basic Drive Module (BDM) Motor Trans- mission Load- machine Often named as Frequency Converter Fig. 4.5 Defi nition of CDM and PDS The IE classes are defi ned in relation to a reference CDM (RCDM). By having the same scale for all power sizes the classes are defi ned by relative losses. CDM with relative losses in the range of ± 25% of the RCDM is classifi ed as IE1. CDM with higher losses are grouped in IE0 while CDM with lower losses are in class IE2 (see Fig. 4.7 Defi nition of CDM and PDS effi ciency classes).

The rating does not refl ect the CDM effi ciency at lower speed / torque as it’s determined at 100% relative speed and 90% relative torque-producing current. For verifi cation the CDM is tested with all included components at a defi ned test load. Fine tuning or a special test mode is not allowed. Transmission Even though the kind of transmission can have a huge impact on the system effi ciency, no effi ciency classes are defi ned. The following table gives an indication of typical effi ciencies: Table 4.1 Typical transmission effi ciencies. Fig.

4.6 One Gear Drive is a direct driven motor which comes without gearbox but provides high torque at high effi ciency Direct driven 100% Spur gear 98% Bevel gear 98% Worm gear 95% Flat belt 96...98% V-belt 92...94% Tooth belt 96...98% Chain 96...98%