111 Saving Energy with Frequency Converters Principle torque and current curves for starting a motor with constant load direct on mains, by a softstarter and by a frequency converter are shown in Fig. 4.9 Comparison motor start direct on mains with motor started by a softstarter and Fig. 4.10 Comparison motor start direct on mains with a motor started by a frequency converter at 160% overload. The curves will look diff erent with diff erent loads. 4.5 Energy Effi cient Motor Control All motors operate by applying the correct voltage at a given frequency. A rotating shaft does not mean, however, that the motor is operating effi ciently.
For controlling a motor, a control algorithm (U/f, voltage vector, fl ux vector,…) and a control strategy are required. That both components must suit a motor type can easily be seen with motors using permanent magnets. For energy-optimum operation the controller must match the supply voltage waveform as closely as possible to the waveform of the back EMF. Block commutation is used for trapezoidal back EMF and sine commutation for sinusoidal. Fig. 4.11 Block vs. Sine-wave commutation Block commutation is known to have some disadvantages like torque ripple and excessive noise. However both technologies are comparable when it comes to effi ciency.
Control strategies which are often used in diff erent control algorithms are: Constant Torque angle Maximum torque is created when the torque angle is kept constant at 90°. The constant Torque angle strategy keeps the angle constant by controlling the rotor d-axis current to zero while leaving the current vector on the y-axis. ° 6 0° 1 20° 1 80° 24 0° 3 00° 3 60° Blo Sin ck commutatio e commutatio n n