114 Saving Energy with Frequency Converters ( ) Q1 Q2 n1 n2 ѕ Flow is proportional to speed ( ) H1 H2 n1 n2 ѕ Pressure or head is proportional to square of speed 2 ( ) P1 P2 n1 n2 ѕ Power is proportional to cube of speed 3 The fl ow Q increases linearly with increasing speed (RPM), while the pressure/head H increases quadratically and the power consumption P increases cubically. In theory a reduction in speed of 20% results in an energy reduction of 50%. Operating point System characteristic Pressure [bar] Pump characteristic Energy required Flow [Q] Fig.
4.14 Energy required in a variable torque pump application for throttle control In many fan and pumps systems, swirl fl aps, dampers or throttles are used for controlling the fl ow of the system. If a centrifugal pump is controlled using a throttle valve, throttling moves the machine’s working point along the pump characteristic. The reduction in energy requirement achieved is minimal compared with the pump’s nominal operating point. Pump characteristic System characteristic Pressure [bar] Operating point Energy required Flow [Q] Fig. 4.15 Energy required in a variable torque pump application for speed control