159 Interfaces Since FC’s usually only have a serial RS-485 interface available, interface converters are required for implementation. Manufacturer-specifi c solutions in which a particular FC is required are widespread. If the interface specifi cation is published, simple industry- standard converters (such as USB to RS-485) can be used. USB RS485 USB to RS485 converter Fig. 8.6 USB to RS 485 communication FC’s are increasingly being fi tted with USB interfaces for simple data exchange with a PC. Since many PCs have USB interfaces, the use of interface converters is becoming obsolete.

8.4 Fieldbus Interfaces in Frequency Converters The use of modern FC’s without a serial communication interface is almost inconceivable today. In the simplest case, the interface consists of two data lines through which the FC can be controlled, monitored, confi gured and documented. Almost all bus systems enable multiple devices to be on the same network. Compared with conventional FC control via digital and analogue inputs and outputs, there is less cabling involved in serial bus systems, which reduces installation cost. On the other hand, costs are incurred for the interfaces and additional components are required to control the bus system.

Depending on the bus system used, only a few networked devices are necessary to generate considerable cost benefi ts compared with conventional control. Traditional wiring. No fi eldbus. In this type of network, communication between the drive and PLC requires one cable for each parameter that needs to be controlled. The advantage of such a system is that the individual components themselves are relatively cheap, and the system itself is not among the most complex.