93 Frequency Converters and Motors 3.5 Dynamic Brake Operation Machines can create potential or kinetic energy which we want to remove from the machine. Potential energy is caused by gravity, for example when a load is hoisted to a position and being held in position. Kinetic energy is caused by movement, for example a centrifuge running at a given speed which we want to reduce or a trolley to be stopped. The dynamic characteristics of some loads require 4-quadrant operation. A reduction in the stator frequency (and voltage) by the FC allows the motor to act as a generator and convert mechanical energy into electrical energy.
N CW rotation CW rotation T N N T - T T Driving Driving Braking Braking T N N T CCW rotation T - Torque N - Speed - N Fig. 3.10 Four Quadrant operation: Clockwise (CW) and Counter Clockwise (CCW) Motors connected directly to the mains deliver the braking energy straight back to the mains. If a motor is controlled by a FC, the braking energy is stored in the intermediate circuit of the FC. If the braking energy exceeds the power loss of the FC, the voltage in the intermediate circuit increases dramatically (in some cases exceeding 1000 V DC).
If the voltage exceeds the internal voltage limit, the FC is then switched off for self- protection and usually issues an alarm message or error code “over voltage”. Measures must be taken to prevent the FC being tripped if the motor feeds back excessive braking energy.