HiPhi — 6.2.2 Supply disconnecting (isolating) device

Electrical equipment 6.2 Incoming supply conductor termination and supply disconnecting device 6.2.2 Supply disconnecting (isolating) device Supply disconnecting (isolating) device The purpose of the supply disconnecting device is to disconnect (isolate) a machine from the incoming supply when required. With the exclusion of some excepted circuits, the electrical equipment of the machine will be isolated from the supply when the supply disconnecting device is switched off. This may be necessary, for example, to allow maintenance work.

According to Chapter 5.3 of IEC 60204-1, supply disconnecting devices shall be provided for the following:· For each incoming source of supply to one or more machines For each on-board power supply, e.g. for mobile machines Note Two or more supply disconnecting devices Where two or more supply disconnecting devices are provided, protective interlocks to ensure their correct operation shall also be provided in order to prevent risks to the safety of personnel, or damage to the machine or to the work in progress. Permissible types of supply disconnecting device According to IEC 60204-1, it is permissible to use the following types of supply disconnecting device: According to IEC 60947-3:

switch disconnector, with or without fuses, for utilization category AC-23B or DC-23B According to IEC 60947-6-2: Control and protective switching devices with isolating properties According to IEC 60947-2: Circuit breakers suitable for isolation Any other switching devices that fulfill an IEC product standard, requirements placed on isolating devices and the appropriate utilization category and/or the stress requirements specified in the product standards.

Plug/socket combinations for a flexible cable supply Note For further information, see Chapter SIRIUS 3RA6 compact starters (Page 247) Control Panels compliant with IEC Standards and European Directives 86 Reference Manual, 10/2017, A5E38284819002A/RS-AB/002